Download Maintenance Manual for Laboratory Equipment 2ed by World Health Organization PDF

By World Health Organization

Show description

Read Online or Download Maintenance Manual for Laboratory Equipment 2ed PDF

Best equipment books

Digital Photographer, Issue 174

Within the electronic Photographer Annual, we’ve compiled a wealth of gains and tutorials that cater for everybody, from rookies to veterans. you could get pleasure from revealing interviews with many of the world’s such a lot acclaimed photographers, realize the secrets and techniques to capturing attractive landscapes and lovely photographs with our technical publications, and get expert pointers on snapping weddings, flora and fauna and every little thing in among.

Managing the Effective Use of Equipment Super Series, Fifth Edition (Super Series)

Large sequence are a suite of workbooks to accompany the versatile studying programme particularly designed and constructed through the Institute of management & administration (ILM) to aid their point three certificates in First Line administration. the educational content material can also be heavily aligned to the extent three S/NVQ in administration.

Fluidic Components and Equipment 1968–9

Fluidic parts and kit 1968—9 provides info on quite a lot of fluidic parts, structures, ideas, and gear. a number of the some ways within which fluid interplay can be used to accomplish worthy capabilities are defined, and usual parts, circuits, and platforms are defined.

Additional info for Maintenance Manual for Laboratory Equipment 2ed

Example text

The screen shows an error message. Incorrect operating mode selected. Verify the operation mode selected. Select a valid operation. The screen shows a calibration or error message. There is a calibration error. Recalibrate the pH meter. The calibration of the buffer value is erroneous. Verify the buffer values used. The electrode is dirty. Clean and calibrate the electrode. * The batteries are badly installed. Verify the polarity of the batteries. The batteries are worn out. Replace the batteries.

If the scale registers less than 100, it is necessary to unwind the screw anticlockwise. Repeat the process until the balance is adjusted (adjusting the zero and the sensitivity). 23 CHAPTER 4 B A L A N C E S 4. Verify the plate’s brake. It is mounted on a threaded axis which touches the plate in order to prevent it from oscillating when the balance is locked. In case of an imbalance, the axis must be rotated slightly until the distance between the break and the plate is zero when the balance is locked.

Process. Verify that the changes and selections are done according to the manufacturer’s instructions. Repeat the selection or change. again. The balance’s reader is unstable. There is vibration on the surface of the table/counter. Place the balance on a stable surface. The front door of the balance is open. Close the front door to measure. The RS232 interface does not function. The interconnection cable is maladjusted. Check the connection of the interconnection cable. The screen shows incomplete readings or is locked.